MBMNTC

Bulk Data Entry Defines a curve moment at a grid point by specifying a vector.

Format

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
MBMNTC SID G1 CID CVID G3/N N N G2  
  INT EID              

Example

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
MBMNTC 3 345   4 0.0 1.0 0.0    
  AKIMA 42              

Definitions

Field Contents SI Unit Example
SID Load set identification number.

No default (Integer > 0)

 
G1 Grid point identification number where the action force is applied.

No default (Integer > 0)

 
CID Coordinate system identification number. Blank or 0 infer the basic coordinate system.

Default = 0 (Integer ≥ 0, or blank)

 
CVID Set identification number of the MBCRV entry that gives the load vs. independent variable measured in the coordinate system defined by CID.

(Integer > 0)

 
G3 Grid point identification number to optionally supply N1, N2, N3 in conjunction with G1.

(Integer > 0)

 
N,N,N Defines the direction of the force vector. At least one of the vector components must be non-zero.

Default = 0.0 (Real)

 
G2 Grid point identification number where the reaction force is applied. If blank or zero, then the force is an action-only force.

Default = 0 (Integer ≥ 0)

 
INT Interpolation type.
AKIMA (Default)
CUBIC
LINEAR

(Character)

 
EID Set identification number of the MBVAR for the independent variable expression.

Default = TIME (Integer ≥ 0 or blank)

 

Comments

  1. This card is represented as a moment load in HyperMesh.