MBMNTE

Bulk Data Entry Defines an expression moment at a grid point by specifying a vector.

Format

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
MBMNTE SID G1 CID EID G3/N N N G2  

Example

(1) (2) (3) (4) (5) (6) (7) (8) (9) (10)
MBMNT 3 345   4 0.0 1.0 0.0    

Definitions

Field Contents SI Unit Example
SID Load set identification number.

No default (Integer > 0)

 
G1 Grid point identification number where the action force is applied.

No default (Integer > 0)

 
CID Coordinate system identification number. Blank or 0 infer the basic coordinate system.

Default = 0 (Integer ≥ 0, or blank)

 
EID Expression identification number of the MBVAR entry that gives the load measured in the coordinate system defined by CID.

No default (Integer > 0)

 
G3 Grid point identification number to optionally supply N1, N2, N3 in conjunction with G1.

(Integer > 0)

 
N, N, N Defines the direction of the force vector. At least one of the vector components must be non-zero.

Default = 0.0 (Real)

 
G2 Grid point identification number where the reaction force is applied. If blank or zero, the force is an action-only force.

Default = 0 (Integer ≥ 0)