MBSMNTE
Bulk Data Entry Defines an expression scalar moment on two grid points along the specified vector.
Format
(1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) |
---|---|---|---|---|---|---|---|---|---|
MBSMNTE | SID | G1 | G2 | EID | Vx | Vy | Vz |
Example
(1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) |
---|---|---|---|---|---|---|---|---|---|
MBSMNTE | 3 | 345 | 346 | 2 | 0 | 1.0 | 1.0 |
Definitions
Field | Contents | SI Unit Example |
---|---|---|
SID | Load set
identification number. No default (Integer > 0) |
|
G1 | Grid point
identification number. No default (Integer > 0) |
|
G2 | Grid point
identification number. No default (Integer > 0) |
|
EID | Expression
identification number of the MBVAR entry. No default (Integer > 0) |
|
G3 | Grid point
identification number to optionally supply
Vx, Vy, and
Vz in conjunction with
G1. (Integer > 0) |
|
Vx | X component of Vector V | |
Vy | Y component of Vector V | |
Vz | Z component of Vector V |
Comments
- MBSMNTE applies a scalar action-reaction moment on G1 and G2 along the vector defined by Vx, Vy, and Vz.
- The action moment is applied to G1 and the reaction moment is applied to G2.
- Right hand rule defines the positive moment.