PCONVLIB
Bulk Data Entry Defines the external function to be called to calculate time and temperature-dependent free-convection coefficient in a convection element.
Format
(1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) |
---|---|---|---|---|---|---|---|---|---|
PCONVLIB | PID | GROUP | FUNCT |
Definitions
Field | Contents | SI Unit Example |
---|---|---|
PID | Convection property
identification number. 1 No default (Integer > 0) |
|
GROUP | Defines the
shared/dynamic library to be used. Refers to an existing LOADLIB entry in the input deck. No default (Character) |
|
FUNCT | Defines the external
function to be used. No default (Character) |
Comments
- The property identification number (PID) must match the corresponding identification number on the PCONV entry.