With only a few exceptions, all analysis entities are supported in SimSolid. However, there are instances where mapping may be
ambiguous. Any items that cannot be reapplied will be marked in red in the project
tree.All red entities must be resolved before the new analysis can be started.
For connections and contact conditions, SimSolid will
use automatic settings to reapply missing connections.
-
Review SimSolid automatic connection/contact
condition resolution settings:
- Double-click on the desired connection/contact condition to
edit.
- Right-click on the desired connection/contact condition and choose
Accept contact condition(s) in red to accept
SimSolid's resolution.
-
For boundary conditions in red, double-click to open the definition
dialog.
-
Reselect the missing location (face, edge, spot, or other).
-
Click OK.
The red will be removed. You can now begin the analysis.