Results Info
This dialog provides summary information for all parts in a given Project Tree branch.
To access the dialog, in the Project Tree right-click any Results and select Info info from the context menu.
- Analysis runtime – total wall time required to run the analysis. This time includes geometry handling, solver adaptive passes and results evaluation.
- Geometry handling time – time required to prepare the model for analysis.
- Display evaluation time – time required to create the output results values.
- Max number of equations – this is the maximum number equations used in any single pass of the solver. Note this is not equivalent to number of DOF in traditional FEA. Since higher order equations are used in SIMSOLID, this value will usually be significantly less than a DOF number given in traditional FEA.
- Number of adaptive solution passes – number of time the equations are solved.