Connection Review
A table that shows all connections in a specified design study.
This function is located on the Connections workbench toolbar. Click the (Review regular connections) icon to open the dialog.
Select a column heading to sort the table. Select a row and the corresponding connection will be highlighted in the graphical display along with its associated parts. Multiple rows can be selected using the SHIFT and CTRL keys. The Zoom-in button (plus sign with hour glass) will zoom the view to the selected connection(s). Connections can be deleted directly from the dialog using the delete button.
Connection table attributes
- Part 1 & Part 2
- These are the two parts referenced by the connection. Note that self-contact is possible using the manual connection creation dialog.
- Max allowable gap & Max allowable penetration
- These are the user specified values.
- Found gap or penetration
- This is the value found by the connection search algorithm. Positive values are gaps and negative values are penetrations.
- Resolution
- This is the user specified resolution level used in the gap search algorithm. Possible values are Normal, Increased and High. Note that Increased is 4X and High is 16X the resolution of Normal search.
- # of points
- This is a relative measure of the accuracy of the connection representation. Higher numbers are better. Connections with thin cross sections and low # of points may cause hinges and numeric instability.