Bushing Property File
The Altair Bushing Model reads a property file that contains all of the information required for a bushing at run-time. This property file is known as the Bushing Property file or General Bushing System property file and uses the extension .gbs.
The following table shows the structure of the .gbs file:
[HEADER]
[UNITS]
[GLOBAL]
[DIRECTIONS]
[FRICTION]
[SPLINE_STIFFNESS_FX] [SPLINE_STIFFNESS_FY] [SPLINE_STIFFNESS_FZ]
[CONSTANT_STIFFNESS_FX] [CONSTANT_STIFFNESS_FY] [CONSTANT_STIFFNESS_FZ]
[CUBIC_SIFFNESS_FX] [CUBIC_STIFFNESS_FY] [CUBIC_STIFFNESS_FZ]
[CONSTANT_DAMPING_FX] [CONSTANT_DAMPING_FY] [CONSTANT_DAMPING_FZ]
[RUBBER_DAMPING_FX] [RUBBER_DAMPING_FY] [RUBER_DAMPING_FZ]
[HYDROMOUNT_DAMPING_FX] [HYDROMOUNT_DAMPING_FY] [HYDROMOUNT_DAMPING_FZ]
[SPLINE_STIFFNESS_TX] [SPLINE_STIFFNESS_TY] [SPLINE_STIFFNESS_TZ]
[CONSTANT_STIFFNESS_TX] [CONSTANT_STIFFNESS_TY] [CONSTANT_STIFFNESS_TZ]
[CUBIC_STIFFNESS_TX] [CUBIC_STIFFNESS_TY] [CUBIC_STIFFNESS_TZ]
[CONSTANT_DAMPING_TX] [CONSTANT_DAMPING_TY] [CONSTANT_DAMPING_TZ]
[RUBBER_DAMPING_TX] [RUBBER_DAMPING_TY] [RUBBER_DAMPING_TZ]
[HYDROMOUNT_DAMPING_TX] [HYDROMOUNT_DAMPING_TY] [HYDROMOUNT_DAMPING_TZ]
The .gbs file uses the TeimOrbit format organized into the following blocks:
Block Type | Description |
---|---|
HEADER | Mandatory block specifying the file type, version, and format information for use by file readers. |
UNITS | Mandatory block that specifies the unit system for parameter values in the property file. This block enables file readers to convert the parameter values in the property file to those used in the simulation. |
GLOBAL | Mandatory block specifying whether or not to couple the X-, Y-, and Z-direction force computations and the X-, Y-, and Z-direction moment computations. |
DIRECTIONS | Mandatory block that specifies the force formulations active for each force and moment direction. |
PARAMETER | Parameter blocks for the active force methods for each direction.
For each force direction of interest the .gbs
file contains six blocks. These are shown in brown in the figure
below. In order to conserve space, the force blocks are shown in
multiple columns, though in the file they are organized one below
the other. Since six possible directions of interest exist, the
.gbs file can contain up to 36 blocks of
information containing the force data. The string, FX, FY, FZ, TX, TY, or TZ, is appended to the block name to identify the direction, for example: [CONSTANT_STIFFNESS_FZ]. Force models selected in the ACTIVITY table must have a corresponding parameter block in the .gbs file. Parameter blocks are available for the following force methods: |
FRICTION | Friction blocks support the parameters for the LuGre friction model—a model that supports both static and dynamic friction. |