Create an Order (scaled) vs. an RPM Waterfall Plot
- From the HyperGraph 3D toolbar, click the Waterfall icon, .
- Under Plot type:, select Order (scaled) from the first drop-down menu and Input magnitude from the second drop-down menu.
- Under Data curves:, enter a p#w#c#.vector curve reference in the Response= field manually, or press Shift and left-click an RPM curve in HyperGraph 3D.
Or
-
Use the curve selector.
- Click the curve selection button, , in the Response text box to display the Response dialog.
- Choose a curve from the tree and click Select.
- You can also click Preview to view the curve before selecting it.
- Click Close to close the Response dialog.
- Under Data curves:, enter a p#w#c#.vector curve reference in the Input= field manually, or press Shift and left-click an RPM curve in HyperGraph 3D. Or, use the curve selector. See Step 3.
- Under Waterfall slices:, select Number: and enter the number of slices for the waterfall plot.
Or
- Select Step size: and enter a step size based on the time vector of the response curve.
- Click Apply.