Use the Parameters Browser to parameterize the contents of a session file or report template and automate a variety of analysis processes with
the Parameters Browser.
Explore, organize and manage your personal data, collaborate in teams, and connect to other data sources, such as
corporate PLM systems to access CAD data or publish simulation data.
Overview of external readers and the Altair Binary Format, the generic ASCII reader, running HyperWorks in batch mode, using Tcl/Tk commands, translators, and result math.
New design point config beam is available with three types: beam, beam
member and beam shell. The latter supports the free body section as a
design point that enables you to perform beam certification methods on
shell elements.
Two methods are shipped with the installation: Beam Compressive
Crippling fσx<0,MS=σx/Fcc−1;withFcc=Fcy*(1−Kcrippling*(L’/p)/π*sqrt(E/Fcy)) and Beam Axial stress fσx>0,MS=σx/Ftu−1;ifσx<0,MS=σx/Fcy−1.
Chain Methods
A method can take its arguments as a result from a previous method. This
enables you to chain methods one after the other and include some
sorting, either spatial aggregation or loadcase enveloping.
Restriction: JointLoad method for Rivet is not valid for
method chaining in this release.
Enhancements
Dockable Certification Browser
Aerospace > Certification > Certify is changed to Aerospace >
Certification > Certification Browser and is now an (un) dockable
browser.
Contouring Method
Enhanced contouring user interface to support sorting options. Depending
on the method output and design point config, the following values are
available: per loadcase, per layer and on element vs on design
point.
Loadcase and layer selection, if applicable, can be set to Envelope. The
sort key (min|max|absmin|absmax) will be applied to perform aggregation
lively on contour. Similarly, if method output is per element but you
select the Entity Column as DDP aggregation is performed using the same
sorting key.
Restriction: Only one key is valid for all
aggregations at a time.
Consolidated Table
Whenever multiple methods are assigned to a design point set, a
consolidated table is added to find most critical methods per location.
Method registration needs to tag one output as Margin of safety to be
considered as a comparison key and be registered in the consolidated
table. Contour invoked from design point set level will select the
consolidated table. The sort key will be used to compare method MS.
API to run method on mark of element
The *rundesignmethod API can now run a method directly on a mark of
element without design points.