AcuSolve Set Up Features
The following AcuSolve set up features are supported in Engineering Solutions via the Solver Browser.
Problem Description
- Title
- Analysis type (Steady State or Transient)
- Flow equation (Navier Stokes)
- Abs. pressure offset
- Temperature equation (Advective Diffusive or None)
- Abs. temperature offset
- Radiation equation (Enclosure or None)
- Turbulence model (Laminar, Spalart Allmaras, SST, K Omega, Detached Eddy Simulation, SST DES, Dynamic LES, Classical LES)
- Mesh type (Fixed or Fully Specified)
Solver Settings
- Max time steps
- Final time
- Initial time increment
- Auto time increment
- Multiplier Function
- Convergence tolerance
- Min stagger iterations
- Max stagger iterations
- Relaxation factor
- Flow
- Temperature
- Temperature flow
- Enclosure radiation
- Turbulence
For full support of all AcuSolve features, use AcuConsole. A model can be transferred from Engineering Solutions to AcuConsole by clicking the icon in the CFD toolbar.