Load Step: CRADIATE
In the CRADIATE dialog, define the *CRADIATE cards on node sets.
To open this dialog from the Load Step dialog, select CRADIATE from the tree and a load collector from the Load collector table.
Load Step: CRADIATE: Define Tab
In the Define tab, define a *CRADIATE card on node sets only.
*CRADIATE on individual nodes is not supported.
Column | Description |
---|---|
Nodeset | The name of the node sets. Node sets are added or removed using → or ←, respectively. |
Area | The area associated with the nodes. |
Sink temp | Ambient reference temperature. |
Emissivity | Surface emissivity. |
For tips on entering information and navigating in the Define tab, see Step Manager Tab Environment.
Button | Action |
---|---|
Review/Reset Set | Reviews the selected node sets by highlighting them in the HyperMesh graphics. Right-click Review to clear the review selections. |
Create/Edit Set.. | Opens the Entity Sets panel in HyperMesh. When you finish creating/editing the set, click return. The Step Manager is updated with the new set appearing in the node set list. |
→ | Add the selected node set from the drop-down menu to the data line table on the right. |
← | Delete the selected node set from the data line table. |
Review | Reviews the selected node set in the data line table. Right-click Review to clear the highlighted selections. |
Update | Updates the HyperMesh database with the data lines defined in the table. By default, HyperMesh does not create a display for loads defined with sets. |
Load Step: CRADIATE: Delete Tab
In the Delete tab, delete *CRADIATE and other loads.
Option | Description |
---|---|
All loads in current collector | The Delete button deletes all the loads from the current load collector. |
All 'CFILM' in current collector | The Delete button deletes only *CRADIATE loads from the current load collector. |
By selection | The Pick Loads button opens the HyperMesh
load selector panel. Pick the loads you want to delete and click
proceed. The corresponding Reset button resets the selected loads. The Delete button deletes the selected loads. |
Load Step: CRADIATE: Parameter Tab
In the Parameter tab, define optional parameters for the *CRADIATE card.
The supported parameters include: Amplitude curve, OP, and Region Type.
Click Update to activate the optional parameter selection in the HyperMesh database.