*CE_FE_RegisterSharedEntities
Registers pre-existing entities to a single connector.
Syntax
*CE_FE_RegisterSharedEntities connector_id entity_type_string_array number_of_strings id_integer_array number_of_integers
Type
HyperMesh Tcl Modify Command
Description
Registers pre-existing entities to a single connector.
Note that a single entity can be registered with multiple connectors.
Inputs
- connector_id
- The ID of the connector to register to.
- entity_type_string_array
- The ID of the string array containing the additional entity types to register. The array is created using the *createstringarray command. This should always be set to 1.
- number_of_strings
- Integer indicating the size (number of entity types) in the string array created using *createstringarray.
- id_integer_array
- The ID of the integer array containing the entity IDs to register. The array is created using the *createarray command. This should always be set to 1.
- number_of_integers
- Integer indicating the size (number of IDs) in the integer array created using *createarray.
Example
Change connector 10 to the user-control mode:
*CE_SetSpecificDetailById 10 2 1 0;
Create the necessary arrays to register component 3, property 7, material 8, set 12 and group 14:
*createstringarray 5 "component" "property" "material" "set" "group";
*createarray 5 3 7 8 12 14;
Register the entities with connector 10:
*CE_FE_RegisterSharedEntities 10 1 5 1 5;
Change connector 10 back to normal control mode (optional):
*CE_SetSpecificDetailById 10 2 0 0;
Errors
if { [ catch {command_name...} ] } {
# Handle error
}
Version History
2017.1