*penetrationdisplay
Displays the amount of penetration through nodes, vectors, or contour.
Syntax
*penetrationdisplay contact_thickness part_thickness_scale display_mode normal_scale label segment_orientation magnitude_mode
Type
HyperMesh Tcl Modify Command
Description
Displays the amount of penetration through nodes, vectors, or contour.
Inputs
- contact_thickness
- Supplied value of the contact thickness.
- part_thickness_scale
- Supplied value of the part thickness scale.
- display_mode
- Type of mode used to display penetration.
- 0 - Nodes
- 1 - Normal
- 2 - Contour
- normal_scale
- Greater than zero - uniform size or % of magnitude of vectors.
- label
- The vector label option.
- 0 - Vector labels off
- 1 - Vector labels on
- segment_orientation
- Flag for taking element normal into consideration for checking penetration.
- 0 - Elements normal will not be considered
- 1 - Elements normal will be considered
- magnitude_mode
-
- 0 - Uniform size
- 1 - Percentage of magnitude
Example
For displaying the amount of penetration if a contact thickness supplied is 1.5, part thickness scale supplied is 1.0, display mode is normal, percentage of magnitude used is 50, vector labels are on, and segment orientation and percentage of magnitude are used:
*penetrationdisplay(1.5, 1, 1, 0.5, 1, 1, 1)
The *penetrationcheck(), penetrationchecktwo(), or penetrationrecheck() command is required.
Errors
None.